Specifications and other information of Bitcoin Miner S19 XP Hyd. in the tables below:
Product Glance | Value |
Model | S19 XP Hyd. |
Version | k0-10 |
Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
Typical hashrate, TH/s(1-1) | 257 |
Power on wall @35°C(1-2), Watt(1-1) | 5346 |
Power efficiency on wall @35°C(1-2), J/T(1-1) | 20.8 |
Detailed Characteristics | Value |
Power Supply | |
Phase | 3 |
Input voltage, Volt(2-1) | 380~415 |
Input frequency range, Hz | 50~60 |
Input max current, Amp | 12 |
Hardware Configuration | |
Network connection mode |
RJ45 Ethernet 10/100M |
Server Size(Length*Width*Height, w/o package),mm | 410*170*209 |
Server Size(Length*Width*Height, with package),mm | 570*316*430 |
Net weight, kg | 12.8 |
Gross weight, kg | 14.1 |
Environment Requirements |
|
Inlet coolant temperature, ℃ | 20~40 |
Coolant flow, L/min | 8.0~10.0 |
Coolant pressure, bar | ≤3.5 |
Working coolant(2-2) | Antifreeze/ Pure water/Deionized water |
Coolant pH value |
Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water: 8.5~9.5 |
Diameter of coolant pipe connector, mm | OD10 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10%~90% |
Notes:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
(1-2) Inlet water temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!