S19j Pro+ 120T
Product Glance |
Value |
Version | S19j Pro+ |
Model No. | j1-12 |
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 120 + 3% |
power on wall@25℃, Watt | 3300 ± 5% |
power efficiency on wall @25°C, J/TH | 27.5 ± 5% |
Detailed Characteristics | Value |
Power Supply | |
Power supply AC input voltage, Volt (1-1) | 200~240 |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp (1-2) | 20(1-3) |
Hardware Configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server Size (Length*Width*Height, w/o package), mm(2-1) | 400*195*290 |
Server Size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg (2-2) | 13.70 |
Gross weight, kg | 15.74 |
Environment Requirements | |
Operation temperature, °C | 0~40 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Operation altitude, m (3-1) | ≤2000 |
S19j Pro+ 117T
Product Glance |
Value |
Version | S19j Pro+ |
Model No. | j1-12 |
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 117 + 3% |
power on wall@25℃, Watt | 3218 ± 5% |
power efficiency on wall @25°C, J/TH | 27.5 ± 5% |
Detailed Characteristics | Value |
Power Supply | |
Power supply AC input voltage, Volt (1-1) | 200~240 |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp(1-2) | 20(1-3) |
Hardware Configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server Size (Length*Width*Height, w/o package), mm(2-1) | 400*195*290 |
Server Size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg(2-2) | 13.70 |
Gross weight, kg | 15.74 |
Environment Requirements | |
Operation temperature, °C | 0~40 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Operation altitude, m(3-1) | ≤2000 |
S19j Pro+ 113T
Product Glance |
Value |
Version | S19j Pro+ |
Model No. | j1-12 |
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 113 + 3% |
power on wall@25℃, Watt | 3108 ± 5% |
power efficiency on wall @25°C, J/TH | 27.5 ± 5% |
Detailed Characteristics | Value |
Power Supply | |
Power supply AC input voltage, Volt (1-1) | 200~240 |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp(1-2) | 20(1-3) |
Hardware Configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server Size (Length*Width*Height, w/o package), mm(2-1) | 400*195*290 |
Server Size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg(2-2) | 13.70 |
Gross weight, kg | 15.74 |
Environment Requirements | |
Operation temperature, °C | 0~40 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Operation altitude, m(3-1) | ≤2000 |
S19j Pro+ 109T
Product Glance |
Value |
Version | S19j Pro+ |
Model No. | j1-12 |
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 109 + 3% |
power on wall@25℃, Watt | 2998 ± 5% |
power efficiency on wall @25°C, J/TH | 27.5 ± 5% |
Detailed Characteristics | Value |
Power Supply | |
Power supply AC input voltage, Volt (1-1) | 200~240 |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp(1-2) | 20(1-3) |
Hardware Configuration | |
Network connection mode | RJ45 Ethernet 10/100M |
Server Size (Length*Width*Height, w/o package), mm(2-1) | 400*195*290 |
Server Size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg(2-2) | 13.70 |
Gross weight, kg | 15.74 |
Environment Requirements | |
Operation temperature, °C | 0~40 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Operation altitude, m(3-1) | ≤2000 |
Notes:
(1-1) Caution: Wrong input voltage may probably cause server damaged.
(1-2) Max condition: temperature 40°C, altitude 0m.
(1-3) Two AC input wires, 10A per wire.
(2-1) Including PSU size.
(2-2) Including PSU weight.
(3-1) When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m.